DX-102B Portable Gauss Meter

DX-102B is a portable AC and DC gaussmeter used for measuring the surface magnetic field of permanent magnets and the working magnetic field of DC motor and magnetic separators.   DC Measurement Range: 30kG, 3kG, 300G; AC Measurement Range: 3Kg, 300G; Dimension: 173×91×42mm.

DX-102B gaussmeter can display N/S, with the high resolution of 0.1G, it can be used for detecting the residual magnetic of machining, the remanence of work-piece and controlling the magnetic situation of plating materials, also detecting the magnetism of motors. With AC measurement function, it can be applied for detecting AC space magnetic field distribution.

DX-102B gaussmeter has two 64 readings memory, which is convenient for recording measurement data in real time. It can be connected to computer by the USB interface, and quickly form the magnetic field monitoring and measurement system by dedicated acquisition software.

Features:

Portable, convenient to handle and store, for on site measurement
Automatically shut down time can be set, continuously use for more than 30 hours (turn off back-light)
DC/AC magnetic field
DC/AC maximum value hold
DC field polarity judge function
Probe automatic zero, relative measurement, upper and lower limit alarm sorting
Units: G, T, Oe, A/m
Two 64 readings memory for recording measurement data in real time
USB interface and dedicated acquisition software
Transverse probe/ axial probe with independent calibration value

Technical parameters:

Power four AA batteries (alkaline battery is recommended)
Display 3¾digital LCD display
DC Measurement Range: 30kG, 3kG, 300G
Resolution: 10G, 1G, 0.1G
Accuracy: (2%of reading +0.1%of range)
  (B<20kG, probe temperature15-35℃)
Temperature coefficient: Maximum ±(0.06% of reading+0.01G)/℃
  probe temperature 15-35℃
Display update rate: 2.5 rgd/s
AC Measurement Range: 3Kg, 300G
Resolution: 1G, 0.1G
Bandwidth: 10Hz-10kHz (sine magnetic field)
Accuracy: ±(5%of reading +0.2%of range)
  (effective range, 1kHz sine magnetic field)
Effective measurement range >0.33%range
Rated measurement range >1%range
Zero deviation : <0.2%range
Temperature coefficient: Maximum ±(0.06%of reading)/℃
  probe temperature 15-35℃
Display update rate: 2.5 rgd/s
Application Environment Instrument: 15-35℃(rated accuracy)
  35-45℃ (accuracy reduced by 0.2%)
Probe: 15-35℃ (rated accuracy)
  35-45℃(accuracy reduced by 1%)
Humidity: 35~75%
Interface: 5-core probe socket
Dimension: L173*W91*T42mm

   

Home    Gauss Meter    DX-102B Portable Gauss Meter